Application |
Application | for Pt100 and Pt1000 measuring elements |
Electrical data |
Operating voltage [V] | 20…32 DC |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1 |
Integrated watchdog | yes |
Inputs / outputs |
Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs |
Total number of outputs | 1 |
Output signal | analogue signal; IO-Link; (configurable) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20 |
Max. load [Ω] | 300 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
Measuring range | |
Factory setting | -50…300 °C |
Accuracy / deviations |
Precision analogue output [K] | ± 0,3 + (± 0,1 % MS) |
Temperature coefficient [% of the span / 10 K] | 0,1 |
Response times |
Max. measuring/display cycle [ms] | 100 |
Interfaces |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.0 |
Operating conditions |
Ambient temperature [°C] | -25…70 |
Storage temperature [°C] | -40…85 |
Protection | IP 67 |
Tests / approvals |
EMC | |
Shock resistance | DIN IEC 68-2-27 | 50 g (11 ms) | |
Vibration resistance | DIN IEC 68-2-6 | 20 g (10…2000 Hz) | |
MTTF [years] | 449 |
Mechanical data |
Weight [g] | 40.5 |
Dimensions [mm] | M12 x 1 |
Thread designation | M12 x 1 |
Materials | PA; PET; Sealing: FKM; Lock nut: stainless steel (1.4404 / 316L); plug: TPU |
Material nut | stainless steel (1.4404 / 316L) |
Remarks |
Remarks | operating voltage “supply class 2” according to cULus | MS = set measuring span | |
Pack quantity | 1 pcs. |
Electrical connection |
Connection | Connector: 1 x M12; Moulded body: TPU; Locking: stainless steel (1.4404 / 316L); Contacts: gold-plated |
评价