Application |
Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) |
Media | liquids and gases |
Pressure rating [bar] | 400 |
Electrical data |
Operating voltage [V] | 18…32 DC; (“supply class 2” to cULus) |
Current consumption [mA] | < 50 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1 |
Integrated watchdog | yes |
Inputs / outputs |
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 250 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20 |
Max. load [Ω] | 500 |
Analogue voltage output [V] | 0…10 |
Min. load resistance [Ω] | 2000 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
Measuring range | |
Factory setting | -50…150 °C |
Set point SP | -49.8…150 °C | -57.6…302 °F | |
Reset point rP | -50…149.8 °C | -58…301.6 °F | |
Analogue start point | |
Analogue end point | |
In steps of | |
Resolution |
Resolution of switching output [K] | 0.1 |
Resolution of analogue output [K] | current output: MS / 4096; voltage output: MS / 3561 |
Resolution of display [K] | 0.1 |
Accuracy / deviations |
Switch point accuracy [K] | ± 0,3 + (± 0,1 % MS) |
Precision analogue output [K] | ± 0,3 + (± 0,1 % MS) |
Display accuracy [K] | ± 0,3 + (± 0,1 % MS) |
Temperature coefficient [% of the span / 10 K] | 0,1; (in case of deviation from the reference condition 25 ± 5 °C) |
Response times |
Dynamic response T05 / T09 [s] | 1 / 3; (to DIN EN 60751) |
Software / programming |
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
Interfaces |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
Operating conditions |
Ambient temperature [°C] | -25…80 |
Storage temperature [°C] | -40…100 |
Protection | IP 67 |
Tests / approvals |
EMC | DIN EN 61000-6-2 | | DIN EN 61000-6-3 | | |
Shock resistance | DIN IEC 68-2-27 | 50 g (11 ms) | |
Vibration resistance | DIN EN 60068-2-6 | 20 g (10…2000 Hz) | |
MTTF [years] | 207 |
UL approval | |
Mechanical data |
Weight [g] | 213.5 |
Materials | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts) | stainless steel (1.4404 / 316L); O-ring: FKM |
Process connection | threaded connection G 1/4 |
Installation length EL [mm] | 50 |
Displays / operating elements |
Display | Display unit | 2 x LED, green | switching status | 2 x LED, yellow | measured values | alphanumeric display, red/green 4-digit | |
Remarks |
Remarks | MS = set measuring span | The values for accuracy apply to flowing water. | |
Pack quantity | 1 pcs. |
Electrical connection |
Connection | Connector: 1 x M12; Contacts: gold-plated |
评价