Application |
Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) |
Media | liquids and gases |
Medium temperature [°C] | -40…145 |
Pressure rating [bar] | 400 |
Electrical data |
Operating voltage [V] | 9.6…32 DC; (“supply class 2” to cULus) |
Current consumption [mA] | < 30 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 0.5 |
Inputs / outputs |
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
Total number of outputs | 2 |
Output signal | switching signal |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | complementary |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 500 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
Measuring range | |
Set point SP | |
Reset point rP | |
Accuracy / deviations |
Temperature drift per 10 K [K] | 0.1 **) |
Repeatability [K] | ± 0,1 |
Setting accuracy [K] | ± 3 |
Response times |
Dynamic response T05 / T09 [s] | 1 / 3; (to DIN EN 60751) |
Software / programming |
Adjustment of the switch point | setting rings |
Operating conditions |
Ambient temperature [°C] | -40…80 |
Note on ambient temperature | at medium temperature: < 80 °C | -40…50 °C | at medium temperature: < 145 °C | |
Storage temperature [°C] | -40…100 |
Protection | IP 67 |
Tests / approvals |
EMC | DIN EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 10 V/m | DIN EN 61000-4-4 Burst | 2 kV | EN 61000-4-6 HF conducted | 10 V | |
Shock resistance | DIN IEC 68-2-27 | 50 g (11 ms) | |
Vibration resistance | DIN EN 60068-2-6 | 20 g (10…2000 Hz) | |
MTTF [years] | 643.1 |
UL approval | |
Mechanical data |
Weight [g] | 100.5 |
Materials | stainless steel (1.4404 / 316L); PC; PBT; FKM |
Materials (wetted parts) | stainless steel (1.4404 / 316L); FKM |
Process connection | threaded connection 1/4″ NPT |
Probe diameter [mm] | 6 |
Installation length EL [mm] | 50 |
Displays / operating elements |
Display | operation | LED, green | switching status | LED, yellow | |
Remarks |
Remarks | **) in case of deviation from the reference condition 25 °C | The values for accuracy apply to flowing water. | |
Pack quantity | 1 pcs. |
Electrical connection |
Connection | Connector: 1 x M12; Contacts: gold-plated |
评价
目前还没有评价