Application |
Function principle | Diffuse reflection sensor |
Electrical data |
Operating voltage [V] | 10…30 DC |
Current consumption [mA] | 16; (24 V) |
Protection class | III |
Reverse polarity protection | yes |
Type of light | red light |
Wave length [nm] | 650 |
Outputs |
Electrical design | NPN |
Output function | light-on/dark-on mode; (selectable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | 1000 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Detection zone |
Range [mm] | 1…100; (white paper 200 x 200 mm) |
Range on white object (90 % remission) [mm] | 1…100 |
Range on grey object (18 % remission) [mm] | 8…100 |
Range on black object (6 % remission) [mm] | 12…100 |
Range adjustable | yes |
Max. light spot diameter [mm] | 2 |
Light spot dimensions refer to | at maximum range |
Background suppression available | yes |
Interfaces |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
IO-Link device ID | 526 d / 00020E h |
Profiles | Smart Sensor: Device Identification; Device Diagnosis; Teach Channel; Switching Channel; Process Data Variable |
SIO mode | yes |
Required master port type | A |
Operating conditions |
Ambient temperature [°C] | -10…60 |
Protection | IP 65; IP 67 |
Tests / approvals |
EMC | |
Laser protection class | 1 |
Notes on laser protection | Caution: | laser light | laser class: | 1 | | EN / IEC60825-1:2007 | | EN / IEC60825-1:2014 | | Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. | |
MTTF [years] | 513 |
Mechanical data |
Weight [g] | 33.9 |
Housing | rectangular |
Dimensions [mm] | 35.4 x 13 x 21 |
Materials | housing: ABS; PPSU; Sealing: EPDM |
Lens material | |
Lens alignment | side lens |
Displays / operating elements |
Display | switching status | 1 x LED, yellow | operation | 1 x LED, green | |
Remarks |
Remarks | operating voltage “supply class 2” according to cULus | |
Pack quantity | 1 pcs. |
Electrical connection – plug |
Connection | Cable: 0.3 m, PUR, black, Ø 3.7 mm; 3 x 0.25 mm² |
Connection | Connector: 1 x M12 |
Diagrams and graphs |
| x: | distance sensor/object [mm] | y: | min. distance object/background [mm] | 1 = | object black (6 % remission) , background (white 90 % remission) | 2 = | object grey (18 % remission) , background (white 90 % remission) | 3 = | object white (90 % remission) , background (white 90 % remission) | |
| a: | sensor | b: | object | c: | background | x: | distance sensor/object [mm] | y: | min. distance object/background [mm] | |
Other data |
Repeatability: 6 σ |
| repeatability of the measured values | | Abstand | white (90 % remission) | black (6 %…90 % remission) | 20 mm | 0.1 mm | 0.5 mm | 50 mm | 0.2 mm | 1.0 mm | 100 mm | 0.5 mm | 2.0 mm | | | | | Accuracy | | Abstand | white (90 % remission) | black (6 %…90 % remission) | 20 mm | ± 0.6 mm | ± 0.9 mm | 50 mm | ± 1.5 mm | ± 2.0 mm | 100 mm | ± 3.0 mm | ± 4.0 mm | | | | |
The values apply at | | Extraneous light on the object | < 10 klx | constant ambient conditions | 23 °C / 960 hPa | minimum power-on time in minutes | 10 | IO-Link – measuring mode | |
评价
目前还没有评价