Application |
Application | output of 3D image data |
Electrical data |
Operating voltage [V] | 20.4…28.8 DC; (EN 61131-2) |
Current consumption [mA] | < 2400; (peak current pulsed; typical value: 420; maximum value: 1600) |
Power consumption [W] | 10; (typical value) |
Protection class | III |
Internal lighting | yes |
Inputs / outputs |
Number of inputs and outputs | Number of digital outputs: 2 |
Inputs |
Trigger | 24 V PNP/NPN (IEC 61131-2 Typ 3) |
Outputs |
Total number of outputs | 2 |
Number of digital outputs | 2; (configurable) |
Output function | 24 V PNP/NPN; (EN 61131-2) |
Max. current load per output [mA] | 100 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Detection zone |
Operating distance [mm] | 300…10000 |
Note on operating distance | object size: 200 x 200 mm | reflectivity: 18 % | |
Image resolution [pixels] | 352 x 264 |
Angle of aperture [°] | 40 x 30; (nominal value without lens distortion correction) |
Max. reading rate [Hz] | 25 |
Measuring/setting range |
Measuring range [m] | < 30 |
Software / programming |
Parameter setting options | via PC with ifm Vision Assistant or XML-RPC |
Interfaces |
Communication interface | Ethernet |
Ethernet |
Number of Ethernet interfaces | 1 |
Transmission standard | 10Base-T; 100Base-TX |
Transmission rate | 10; 100 |
Protocol | TCP/IP |
Factory settings | IP address: 192.168.0.69 | subnet mask: 255.255.255.0 | gateway IP address: 192.168.0.201 | |
Operating conditions |
Ambient temperature [°C] | -10…50 |
Storage temperature [°C] | -40…85 |
Protection | IP 65; IP 67 |
Max. immunity to extraneous light [klx] | 8; (with reduced measuring accuracy and repeatability: < 100) |
Tests / approvals |
EMC | DIN EN 61000-6-4 | radiation of interference / industrial environments | DIN EN 61000-6-2 | noise immunity / industrial environments | |
Shock resistance | DIN EN 60068-2-27 | 50 g / (11 ms) not repetitive | DIN EN 60068-2-27 | 40 g / (6 ms) repetitive | |
Vibration resistance | DIN EN 60068-2-6 | 2 g / (10…150 Hz) | DIN EN 60068-2-64 | 2.3 g RMS / (10…500 Hz) | |
Photobiological safety | exempt group; (DIN EN 62471) |
Electrical protection | DIN EN 61010-2-201 | electrical supply only via PELV circuits | |
MTTF [years] | 45.02 |
Mechanical data |
Weight [g] | 785 |
Dimensions [mm] | 72 x 67.1 x 82.6 |
Materials | housing: diecast aluminium; front lens: Gorilla Glass; function display: PA |
Image sensor | PMD 3D ToF-Chip |
Displays / operating elements |
Display | function | 2 LED, green Ethernet operation | switching status | 2 LED, yellow OUT 1 OUT 2 | |
Accessories |
Accessories (supplied) | USB memory stick with software and documentation | Protective covers | |
Remarks |
Pack quantity | 1 pcs. |
Electrical connection – Process connection |
| Connector: 1 x M12 |
Electrical connection – Ethernet |
| Connector: 1 x M12 |
Other data |
Field of view size |
| without lens distortion correction | | with lens distortion correction | | measuring range / distance [m] | Length [m] | Width [m] | Length [m] | Width [m] | 0.50 | 0.27 | 0.36 | 0.26 | 0.35 | 1.00 | 0.53 | 0.73 | 0.52 | 0.69 | 2.00 | 1.07 | 1.46 | 1.04 | 1.39 | 3.00 | 1.60 | 2.19 | 1.56 | 2.08 | 4.00 | 2.13 | 2.92 | 2.08 | 2.78 | 5.00 | 2.67 | 3.65 | 2.61 | 3.47 | |
评价