描述

Application
Media ferrous only
Electrical data
Operating voltage [V] 10…30 DC
Rated insulation voltage [V] 60
Current consumption [mA] < 30
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 0.3
Outputs
Electrical design PNP/NPN; (parameterisable)
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Max. leakage current [mA] 0.1
Permanent current rating of switching output DC [mA] 100
Short-time current rating of switching output [mA] 100
Switching frequency DC [Hz] 300
Notes on switching frequency
suppression of extraneous fields: 10
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Sensing range [mm] 5
Real sensing range Sr [mm] 5 ± 10 %
Operating distance [mm] 0…4.05
Accuracy / deviations
Correction factor steel: 1
Hysteresis [% of Sr] < 10
Switch point drift [% of Sr] 10
Repeatability [% of Sr] 10
Software / programming
Parameter setting options hysteresis / window; switch-off delay; weld-field immunity; switch-on operations; Auto-teach
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles Smart Sensor: Identification and diagnosis; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Teach Channel
SIO mode yes
Required master port type A
Min. process cycle time [ms] 9.6
IO-Link functions (cyclical)
function bit length
process value 16
device status 4
binary switching information 4
IO-Link functions (acyclical) application specific tag; operating hours counter; switching cycles counter
Supported DeviceIDs
Type of operation IO-Link device ID
Default 829d / 00033Dh
Note
For further information please see the IODD PDF file at “Downloads”
Operating conditions
Ambient temperature [°C] -25…80
Storage temperature [°C] -30…85
Protection IP 65; IP 67
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 10 V
EN 55011 class B
Vibration resistance
EN 60068-2-6 Fc 20 g (10…3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes
Shock resistance
EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
Continuous shock resistance
EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
MTTF [years] 1976
UL approval
Ta -25…60 °C
Enclosure type Type 1
voltage supply Limited Voltage/Current
UL Approval no. C011
File number UL E174191
Mechanical data
Weight [g] 81.7
Housing rectangular
Mounting flush mountable
Dimensions [mm] 20 x 8 x 32
Materials diecast zinc anti-spatter; LED window: TPU; potting: PUR
Displays / operating elements
Display
Display operation 1 x LED, green
switching status 1 x LED, yellow
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Cable: 2 m, PUR, Ø 4.9 mm; flame-retardant (IEC 60332-2, UL: FT2); 3 x 0.34 mm²

评价

目前还没有评价


成为第一个“IFM 易福门 MQ2003” 的评价者

咨询