易福门-II5974

易福门-II5974

    • For a precise position monitoring on machines
    • Reliable transmission of the distance as linearised process value via IO-Link
    • Flexible use thanks to large operating temperature range
    • Very high repeatability
    • Normally closed / normally open and PNP/NPN adjustable via IO-Link
    查询

    DATASHEET

  • 描述
  • 用户评价 (0)

描述

Electrical data
Operating voltage [V] 10 … 30 DC
Current consumption [mA] 10
Protection class III
Reverse polarity protection yes
Outputs
Electrical design PNP / NPN
Output function normally open / normally closed; (Selectable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] one hundred
Switching frequency DC [Hz] one hundred
Short-circuit protection yes
Overload protection yes
Detection zone
Switch point IO-Link [mm] 4.3 … 21.5
Measuring range IO-Link [mm] 2.3 … 23
Accuracy / deviations
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.5 / copper: 0.4
Hysteresis [% of Sr] 3 … 15
Linearity error of analogue output [%] ± 2 %; (of the final value of the measuring range)
Repeatability analogue output [%] ± 1 %; (of the final value of the measuring range)
Temperature coefficient ± 0,3 %/K; (of the final value of the measuring range)
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
IO-Link device ID 791d / 000317h
Profiles Smart Sensor: Device Identification; Device Diagnosis; Device Teach Channel; Binary Data Channel; Process Data Variable
SIO mode yes
Required master port type A
Min. process cycle time [ms] 3
Operating conditions
Ambient temperature [°C] -40…85
Protection IP 65; IP 66; IP 67; IP 68; IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 10 V
EN 55011 class B
Vibration resistance
EN 60068-2-6 Fc 20 g (10…3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes
Shock resistance
EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
Continuous shock resistance
EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Fast temperature changes
EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
MTTF [years] 664
UL approval
Ta -25…70 °C
Enclosure type Type 1
voltage supply Limited Voltage/Current
UL Approval no. A008
File number UL E174191
Mechanical data
Weight [g] 113.2
Housing threaded type
Mounting non-flush mountable
Dimensions [mm] M30 x 1.5 / L = 65
Thread designation M30 x 1.5
Materials brass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated
Tightening torque [Nm] 50
Displays / operating elements
Display
switching status 4 x LED, yellow
SIO mode
output stage supplied with current LED, yellow lights
IO-Link mode
target in measuring range LED, yellow lights
target outside measuring range LED, yellow flashing
Accessories
Accessories (supplied)
lock nuts: 2
Remarks
Pack quantity 1 pcs.
Electrical connection – plug
Connector: 1 x M12

评价

目前还没有评价


成为第一个“易福门-II5974” 的评价者

咨询







    X
    咨询