Electrical data |
Operating voltage [V] | 10…30 DC |
Current consumption [mA] | 10 |
Protection class | III |
Reverse polarity protection | yes |
Outputs |
Electrical design | PNP/NPN |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | 600 |
Short-circuit protection | yes |
Overload protection | yes |
Detection zone |
Switch point IO-Link [mm] | 0.7…3.51 |
Measuring range IO-Link [mm] | 0.375…3.75 |
Accuracy / deviations |
Correction factor | steel: 1 / stainless steel: 0.8 / brass: 0.5 / aluminium: 0.5 / copper: 0.4 |
Hysteresis [% of Sr] | 3…15 |
Linearity error of analogue output [%] | ± 2 %; (of the final value of the measuring range) |
Repeatability analogue output [%] | ± 1 %; (of the final value of the measuring range) |
Temperature coefficient | of the final value of the measuring range |
Temperature coefficient [%/K vom MEW] | ± 0,3 |
Interfaces |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 CDV |
IO-Link device ID | 791d / 000317h |
Profiles | Smart Sensor: Device Identification; Device Diagnosis; Device Teach Channel; Binary Data Channel; Process Data Variable |
SIO mode | yes |
Required master port type | A |
Min. process cycle time [ms] | 3 |
Operating conditions |
Ambient temperature [°C] | -40…85 |
Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
Tests / approvals |
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 10 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-6 HF conducted | 10 V | EN 55011 | class B | |
Vibration resistance | EN 60068-2-6 Fc | 20 g (10…3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes | |
Shock resistance | EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes | |
Continuous shock resistance | EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes | |
Fast temperature changes | EN 60068-2-14 Na | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles | |
MTTF [years] | 668 |
UL approval | Ta | -25…70 °C | Enclosure type | Type 1 | voltage supply | Limited Voltage/Current | UL Approval no. | A008 | File number UL | E174191 | |
Mechanical data |
Weight [g] | 28 |
Housing | threaded type |
Mounting | flush mountable |
Dimensions [mm] | M12 x 1 / L = 60 |
Thread designation | M12 x 1 |
Materials | brass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated |
Tightening torque [Nm] | 7 |
Displays / operating elements |
Display | switching status | 4 x LED, yellow | SIO mode | | output stage supplied with current | LED, yellow lights | IO-Link mode | | target in measuring range | LED, yellow lights | target outside measuring range | LED, yellow flashing | |
Accessories |
Accessories (supplied) | |
Remarks |
Pack quantity | 1 pcs. |
Electrical connection – plug |
| Connector: 1 x M12 |
评价