Electrical data |
Operating voltage [V] | 18…30 DC |
Current consumption [mA] | < 47 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Software / programming |
Parameter setting options | display, indication (figure, text, QR code) |
Interfaces |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
IO-Link device ID | 681 d / 00 02 A9 h |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode | no |
Required master port type | A |
Process data binary | 6 |
Min. process cycle time [ms] | 8.4 |
Operating conditions |
Ambient temperature [°C] | 0…60 |
Storage temperature [°C] | -20…80 |
Protection | IP 65; IP 67 |
Tests / approvals |
EMC | DIN EN 61000-6-2 | | DIN EN 61000-6-4 | | |
Shock resistance | DIN EN 60068-2-27 | 20 g (11 ms) | |
Vibration resistance | DIN EN 60068-2-6 | 20 g (10…50 Hz) | |
MTTF [years] | 5.63 |
Mechanical data |
Weight [g] | 174 |
Materials | stainless steel (1.4404 / 316L); PC; PBT-GF30; PPS; FKM; PA 6.6-GF30 |
Displays / operating elements |
Display | colour display | 1,44 “ | resolution pixels | 128 x 128 | | 2 x LED, yellow | |
Remarks |
Pack quantity | 1 pcs. |
Electrical connection |
| Connector: 1 x M12; Contacts: gold-plated |
评价
目前还没有评价