Application |
Application | simple evaluation of rotating and linear movement with regard to underspeed; blocking |
Electrical data |
Nominal voltage AC [V] | 20…250 |
Nominal voltage DC [V] | 20…250 |
Nominal frequency AC [Hz] | 45…65 |
Protection class | II |
Reverse polarity protection | yes |
Outputs |
Total number of outputs | 1 |
Output function | normally open |
Max. voltage drop switching output DC [V] | 7.5 |
Minimum load current [mA] | 6 |
Max. leakage current [mA] | 1.5 |
Permanent current rating of switching output AC [mA] | 350 |
Permanent current rating of switching output DC [mA] | 100 |
Short-time current rating of switching output [mA] | 2200; ((20 ms / 0,5 Hz)) |
Short-circuit proof | no |
Overload protection | no |
Detection zone |
Sensing range [mm] | 10 |
Sensing range adjustable | no |
Real sensing range Sr [mm] | 10 ± 10 % |
Operating distance [mm] | 0…8.1 |
Measuring/setting range |
Setting range [Imp/min] | 5…3600 |
Accuracy / deviations |
Correction factor | steel: 1 / stainless steel: 0.8 / brass: 0.5 / aluminium: 0.5 / copper: 0.4 |
Hysteresis [% of Sr] | 10 |
Response times |
Start-up delay [s] | 12 |
Max. damping frequency [Imp/min] | 4800 |
Software / programming |
Adjustment of the switch point | multiturn potentiometer |
Operating conditions |
Ambient temperature [°C] | -25…80 |
Protection | IP 65; IP 67 |
Tests / approvals |
EMC | |
MTTF [years] | 461 |
Mechanical data |
Weight [g] | 296.5 |
Housing | threaded type |
Mounting | flush mountable |
Dimensions [mm] | M30 x 1.5 / L = 80 |
Thread designation | M30 x 1.5 |
Materials | brass special coating; PA; TPE-U |
Displays / operating elements |
Display | switching status | 2 x LED, yellow | |
Electrical connection |
Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
Accessories |
Accessories (supplied) | |
Remarks |
Remarks | Recommendation Check the safe functioning of the unit after a short circuit. | |
Electrical connection |
Connection | Cable: 2 m, PUR; 2 x 0.5 mm² |
评价