Electrical data |
Operating voltage [V] | 26.5…31.6 DC |
Current consumption [mA] | < 260 |
Protection class | III |
Detection zone |
Sensing range [mm] | 4 |
Operating distance target puck [mm] | 74 |
Operating conditions |
Ambient temperature [°C] | -10…50 |
Protection | IP 5x; (when used outside the hazardous area: IP 67) |
Tests / approvals |
ATEX marking | II 3D Ex tc IIIB T85°Dc IP5X X |
Note on ATEX marking | only in conjunction with the impact protection housing | |
EMC | |
AS-i classification |
AS-i version | 2.1 |
Extended addressing mode possible | yes |
AS-i I/O configuration [hex] | 7 |
AS-i ID code [hex] | A.E |
Mechanical data |
Weight [g] | 783.5 |
Dimensions [mm] | 55 x 60 x 35 |
Materials | housing: PBT orange; cover: PC black; plug: stainless steel; socket: stainless steel; Impact protection housing: stainless steel |
Displays / operating elements |
Display | operation | 1 x LED, green | function | 1 x LED, yellow | |
Accessories |
Accessories (supplied) | Impact protection housing | Mounting plate: 1 | socket head screws: 2 x M5 x 35 | |
Remarks |
Remarks | The outputs must not be set simultaneously if the total load current exceeds 100 mA. | |
Pack quantity | 1 pcs. |
Electrical connection – socket |
Connection | Connector: 1 x M12 |
Electrical connection – plug |
Elektrischer Anschluss | Connector: 1 x M12 |