Application |
Application | totaliser function; for industrial applications |
Installation | connection to pipe by means of an adapter |
Media | water; glycol solutions; coolants; oil |
Note on media | low-viscosity oils with viscosity: 7…40 mm²/s (40 °C) | high-viscosity oils with viscosity: 30…68 mm²/s (40 °C) | |
Medium temperature [°C] | -10…80 |
Pressure rating [bar] | 16 |
Electrical data |
Operating voltage [V] | 19…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] | 100 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 10 |
Inputs / outputs |
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs |
Inputs | counter reset |
Outputs |
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; pulse signal; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20; (scalable) |
Max. load [Ω] | 500 |
Analogue voltage output [V] | 0…10; (scalable) |
Min. load resistance [Ω] | 2000 |
Pulse output | flow rate meter |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
Measuring range | |
Display range | |
Resolution | |
Set point SP | 0.1…50 l/min | 0.005…3 m³/h | |
Reset point rP | 0…49.9 l/min | 0…2.995 m³/h | |
Analogue start point ASP | |
Analogue end point AEP | |
Max. flow rate | |
In steps of | |
Volumetric flow quantity monitoring |
Pulse value | 0.1 l…1 000 000 m³ |
Pulse length [s] | 0,05…2 |
Temperature monitoring |
Measuring range [°C] | -10…80 |
Resolution [°C] | 0.2 |
Set point SP [°C] | -9.8…80 |
Reset point rP [°C] | -10…79.8 |
Analogue start point [°C] | -10…62 |
Analogue end point [°C] | 8…80 |
In steps of [°C] | 0.2 |
Accuracy / deviations |
Flow monitoring |
Accuracy (in the measuring range) | < ± (3 % MW + 0,2 % MEW) / < ± (5 % MW + 0,5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) |
Repeatability | 0,1 l/min; 6 l/h; 0,006 m³/h |
Temperature monitoring |
Accuracy [K] | ± 3 (Q > 1 l/min) |
Response times |
Flow monitoring |
Response time [s] | 0.25; (dAP = 0) |
Delay time programmable dS, dr [s] | 0…50 |
Damping for the switching output dAP [s] | 0…1 |
Temperature monitoring |
Dynamic response T05 / T09 [s] | T09 = 70 (Q > 5 l/min); (water) |
Software / programming |
Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
Operating conditions |
Ambient temperature [°C] | -10…60 |
Storage temperature [°C] | -25…80 |
Protection | IP 67 |
Tests / approvals |
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 10 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-5 Surge | 0,5 kV | EN 61000-4-6 HF conducted | 10 V | |
Shock resistance | DIN IEC 68-2-27 | 20 g (11 ms) | |
Vibration resistance | DIN IEC 68-2-6 | 5 g (10…2000 Hz) | |
MTTF [years] | 175 |
Pressure Equipment Directive | Sound Engineering Practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data |
Weight [g] | 1551.5 |
Materials | housing: AlMgSi0,5 anodised; Sealing: FKM; connector housing: brass Optalloy-plated; PA 6.6; cover film: PA |
Materials (wetted parts) | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 |
Process connection | threaded connection G 3/4 flat seal |
Displays / operating elements |
Display | Display unit | 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) | switching status | 2 x LED, yellow | measured values | alphanumeric display, 4-digit | programming | alphanumeric display, 4-digit | |
Accessories |
Accessories (supplied) | |
Accessories (optional) | | adapter for pipe: 1 x R1/2, stainless steel, E40178 | adapter for pipe: 1 x R1/2, brass, E40151 | |
Remarks |
Remarks | MW = measured value | MEW = Final value of the measuring range | sealing: only with supplied Centellen seals | |
Pack quantity | 1 pcs. |
Electrical connection |
Connection | Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |