IFM-IQ2009

  • Description
  • Reviews (0)

Description

Electrical data
Operating voltage [V] 10…30 DC
Current consumption [mA] < 30
Protection class III
Reverse polarity protection yes
Outputs
Electrical design PNP/NPN; (parameterisable)
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 100
Switching frequency DC [Hz] 300
Short-circuit protection yes
Overload protection yes
Detection zone
Switch point IO-Link [mm] 1.4…7
Measuring range IO-Link [mm] 0.75…7.5
Accuracy / deviations
Correction factor steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3
Hysteresis [% of Sr] 3…15
Note on hysteresis
parameterisable
Linearity error IO-Link [%] ± 2; (of the final value of the measuring range)
Repeatability IO-Link [%] ± 1; (of the final value of the measuring range)
Temperature coefficient [%/K vom MEW] ± 0,6; (-25…70 °C: ± 0,3)
Temperature drift [% vom MEW] ± 10
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles Smart Sensor: Identification and diagnosis; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Teach Channel
SIO mode yes
Required master port type A
Min. process cycle time [ms] 3.2
IO-Link functions (cyclical)
function Bitlänge
process value 16
device status 4
binary switching information 2
IO-Link functions (acyclical) Anwendungsspezifische Markierung; Betriebsstundenzähler
Supported DeviceIDs
Type of operation IO-Link device ID
Default 1106 d / 000452 h
Note
For further information please see the IODD PDF file at “Downloads”
Operating conditions
Ambient temperature [°C] -40…85
Protection IP 65; IP 66; IP 67; IP 68
Tests / approvals
EMC
EN 61000-4-2 ESD 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-6 HF conducted 10 V
EN 55011 class B
Vibration resistance
EN 60068-2-6 Fc 20 g (10…3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes
Shock resistance
EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
Continuous shock resistance
EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Fast temperature changes
EN 60682-2-14 Na TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 10 s 50 cycles
MTTF [years] 787
UL approval
Ta -25…70 °C
Enclosure type Type 1
voltage supply Limited Voltage/Current
UL Approval no. A016
File number UL E174191
Mechanical data
Weight [g] 42.7
Housing rectangular
Mounting flush mountable
Dimensions [mm] 20 x 8 x 32
Materials diecast zinc special coating; sensing face: PBT orange; LED window: TPU; potting: PUR
Displays / operating elements
Display
Display operation 1 x LED, green
switching status 1 x LED, yellow
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Cable: 0.3 m, PUR, Ø 4.9 mm; 3 x 0.34 mm²
Connection Connector: 1 x M12

Reviews

There are no reviews yet.


Be the first to review “IFM-IQ2009”

ENQUIRY







    X