(English) IFM-RO3102

  • Description
  • Reviews (0)

Description

Application
Function principle incremental
Detection system magnetic
Electrical data
Operating voltage [V] 4.75…30 DC
Current consumption [mA] < 150
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 0.5
Max. revolution electrical [U/min] 12000
Outputs
Electrical design HTL/TTL
Switching frequency [kHz] 1000
Factory setting
Output function: HTL (50 mA)
Short-circuit protection yes
Phase difference A and B [°] 90
Measuring/setting range
Resolution 1…10000; (parameterisable; Factory setting: 1024) resolution
Accuracy / deviations
Accuracy [°] 0.1
Software / programming
Parameter setting options Resolution; direction of rotation; HTL; TTL
Interfaces
Communication interface IO-Link
Transmission type COM 2
IO-Link revision 1.1
SIO mode yes
Min. process cycle time [ms] 2.3
Operating conditions
Ambient temperature [°C] -40…85
Storage temperature [°C] -40…85
Max. relative air humidity [%] 95; (condensation not permissible)
Protection IP 65; IP 66; (on the housing: IP 67; on the shaft: IP 65)
Tests / approvals
Shock resistance
100 g
Vibration resistance
20 g
MTTF [years] 292
Mechanical data
Weight [g] 415.5
Dimensions [mm] Ø 58.5 / L = 69
Materials flange: aluminium; housing: stainless steel (1.4521 / 444); plug: stainless steel (1.4401 / 316)
Tightening torque [Nm] < 0.7; (Mounting screw)
Max. revolution, mechanical [U/min] 12000
Max. starting torque [Nm] 2
Reference temperature torque [°C] 20
Shaft design hollow shaft open to one side
Shaft diameter [mm] 15
Shaft material
stainless steel
Installation depth of shaft [mm] 27
Max. axial shaft misalignment [mm] 0,5
Electrical connection
IO-Link Connector: 1 x M12, radial, can also be used axially; Moulded body: stainless steel (1.4401 / 316); Maximum cable length: 100 m; (IO-Link: max. 20 m)

Reviews

There are no reviews yet.


Be the first to review “(English) IFM-RO3102”

INFO LANJUT

    (English)







    X
    INFO LANJUT