Application |
Measuring element | ceramic-capacitive pressure measuring cell |
Application | hygienic systems |
Media | viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C] | -25…125; (150 max. 1h) |
Pressure rating | |
Min. bursting pressure | |
Vacuum resistance [mbar] | -1000 |
Type of pressure | relative pressure |
No dead space | yes |
MAWP (for applications according to CRN) [bar] | 50 |
Electrical data |
Operating voltage [V] | 18…30 DC |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Integrated watchdog | yes |
2-wire |
Current consumption [mA] | 3.5…21.5 |
Power-on delay time [s] | 1 |
3-wire |
Current consumption [mA] | < 45 |
Power-on delay time [s] | 0.5 |
Inputs / outputs |
Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs |
Total number of outputs | 1 |
Output signal | analogue signal |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20; (scalable) |
Max. load [Ω] | 700; (Ub = 24 V; (Ub – 9 V) / 21.5 mA) |
Short-circuit proof | yes |
Overload protection | yes |
Measuring/setting range |
Measuring range | -1…10 bar | -14.5…145 psi | -0.1…1 MPa | |
Analogue start point | -1…8 bar | -14.5…116 psi | -0.1…0.8 MPa | |
Analogue end point | 1…10 bar | 14.5…145 psi | 0.1…1 MPa | |
In steps of | 0.005 bar | 0.1 psi | 0.0005 MPa | |
Factory setting | ASP = 0.0 bar | AEP = 10.0 bar | | |
Accuracy / deviations |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] | < ± 0,2 (nach DIN EN 61298-2); (incl. drift when overtightened, zero point and span error, non-linearity, hysteresis; Turn down 1:1) |
Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,05; (0…70 °C) |
Temperature coefficient span [% of the span / 10 K] | < ± 0,15; (0…70 °C) |
Response times |
Damping for the analogue output dAA [s] | 0…4 |
2-wire |
Step response time analogue output [ms] | 30 |
3-wire |
Step response time analogue output [ms] | 7 |
Interfaces |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
IO-Link device ID | 662 d / 00 02 96 h |
Profiles | Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
SIO mode | no |
Required master port type | A |
Process data analogue | 3 |
Min. process cycle time [ms] | 3.2 |
Operating conditions |
Ambient temperature [°C] | -25…80 |
Storage temperature [°C] | -40…100 |
Protection | IP 67; IP 68; IP 69K |
Tests / approvals |
EMC | DIN EN 61000-6-2 | | DIN EN 61000-6-3 | | |
Shock resistance | DIN EN 60068-2-27 | 50 g (11 ms) | |
Vibration resistance | DIN EN 60068-2-6 | 20 g (10…2000 Hz) | |
MTTF [years] | 323 |
UL approval | |
Mechanical data |
Weight [g] | 302 |
Materials | stainless steel (1.4404 / 316L); PBT |
Materials (wetted parts) | ceramics (99.9 % Al2O3); PTFE; stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4 |
Min. pressure cycles | 100 million |
Tightening torque [Nm] | 20; (recommended tightening torque depends on lubrication, seal and pressure rating) |
Process connection | threaded connection G 1 external thread sealing cone |
Displays / operating elements |
Display unit | bar; psi; MPa |
Remarks |
Pack quantity | 1 pcs. |
Electrical connection |
Connection | Connector: 1 x M12; Contacts: gold-plated |