Electrical data |
Operating voltage [V] | 10…30 DC |
Current consumption [mA] | < 50 |
Protection class | III |
Reverse polarity protection | yes |
Type of light | red light |
Wave length [nm] | 630 |
Outputs |
Electrical design | PNP/NPN; (automatic load detection PNP/NPN) |
Output function | light-on/dark-on mode; (programmable) |
Max. voltage drop switching output DC [V] | 2.5 |
Function check output | yes |
Max. voltage drop of function check output [V] | 2.5 |
Max. current load for function check output [mA] | 10 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | 3000 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Time function [s] | 0.001…0.09 |
Detection zone |
Range [m] | 0…2; (Through-beam sensor) |
Range [mm] | 0…100; (Diffuse reflection sensor) |
Range adjustable | yes |
Operating conditions |
Ambient temperature [°C] | -25…60 |
Protection | IP 65 |
Tests / approvals |
EMC | |
MTTF [years] | 806 |
Mechanical data |
Weight [g] | 67 |
Housing | rectangular |
Dimensions [mm] | 36 x 15 x 60 |
Materials | PPE modified |
Lens alignment | side lens |
Displays / operating elements |
Display | switching status | 1 x LED, yellow | operation | 1 x LED, green | unsafe zone | 1 x LED, red | excess gain | 4 x LED, green | |
Remarks |
Remarks | light-on mode corresponds to the NC output function for through-beam fibre optics | corresponds to the NO output function for diffuse-reflection fibre optics | dark-on mode corresponds to the NO output function for through-beam fibre optics | corresponds to the NC output function for diffuse-reflection fibre optics | operating voltage “supply class 2” according to cULus | |
Pack quantity | 1 pcs. |
Electrical connection |
Connection | Connector: 1 x M12 |
Diagrams and graphs |
excess gain graph | x: | Abstand [mm] | y: | Funktionsreservefaktor | |
Reviews