Electrical data |
Connection to switching amplifiers | yes |
Switching amplifiers | connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mW |
Nominal voltage DC [V] | 8.2; (1kΩ) |
Supply voltage DC [V] | 7.5…15 |
Current consumption [mA] | < 1; (disabled; conductive: > 2,2) |
Protection class | I |
Outputs |
Electrical design | NAMUR |
Output function | normally closed |
Switching frequency DC [Hz] | 40 |
Detection zone |
Sensing range [mm] | 15 |
Sensing range adjustable | yes |
Factory setting sensing range [mm] | 15 |
Accuracy / deviations |
Correction factor | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
Hysteresis [% of Sr] | 1…15 |
Switch point drift [% of Sr] | -15…15 |
Operating conditions |
Ambient temperature [°C] | -20…60 |
Protection | IP 65 |
Tests / approvals |
Approval | DMT 01 ATEX E 020 |
ATEX marking | II 1G Ex ia IIB T6 Ga |
| II 1D Ex ia IIIC T90 °C Da |
EMC | |
MTTF [years] | 838 |
Safety classification |
Max. internal capacitance [nF] | 377.88 |
Max. internal inductance [µH] | 10 |
Mechanical data |
Weight [g] | 1396.5 |
Housing | threaded type |
Mounting | non-flush mountable |
Dimensions [mm] | M34 x 1.5 / L = 92 |
Thread designation | M34 x 1.5 |
Materials | brass white bronze coated; sensing face: PTFE |
Displays / operating elements |
Display | switching status | 1 x LED, yellow | |
Remarks |
Pack quantity | 1 pcs. |
Electrical connection |
Connection | Cable: 20 m, PVC; 3 x 0.5 mm² |
Reviews