Electrical data |
Operating voltage [V] | 10…30 DC |
Current consumption [mA] | < 30 |
Protection class | III |
Reverse polarity protection | yes |
Outputs |
Electrical design | PNP/NPN; (parameterisable) |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | 300 |
Short-circuit protection | yes |
Overload protection | yes |
Detection zone |
Switch point IO-Link [mm] | 1.4…7 |
Measuring range IO-Link [mm] | 0.75…7.5 |
Accuracy / deviations |
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 |
Hysteresis [% of Sr] | 3…15 |
Note on hysteresis | |
Linearity error IO-Link [%] | ± 2; (of the final value of the measuring range) |
Repeatability IO-Link [%] | ± 1; (of the final value of the measuring range) |
Temperature coefficient [%/K vom MEW] | ± 0,6; (-25…70 °C: ± 0,3) |
Temperature drift [% vom MEW] | ± 10 |
Interfaces |
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 CDV |
Profiles | Smart Sensor: Identification and diagnosis; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Teach Channel |
SIO mode | yes |
Required master port type | A |
Min. process cycle time [ms] | 3.2 |
IO-Link functions (cyclical) | function | Bitlänge | process value | 16 | device status | 4 | binary switching information | 2 | |
IO-Link functions (acyclical) | Anwendungsspezifische Markierung; Betriebsstundenzähler |
Supported DeviceIDs | Type of operation | IO-Link device ID | Default | 1106 d / 000452 h | |
Note | For further information please see the IODD PDF file at “Downloads” | |
Operating conditions |
Ambient temperature [°C] | -40…85 |
Protection | IP 65; IP 66; IP 67; IP 68 |
Tests / approvals |
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 10 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-6 HF conducted | 10 V | EN 55011 | class B | |
Vibration resistance | EN 60068-2-6 Fc | 20 g (10…3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes | |
Shock resistance | EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes | |
Continuous shock resistance | EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes | |
Fast temperature changes | EN 60682-2-14 Na | TA = -40°C; TB = 85°C; t1 = 30 min; t2 = < 10 s 50 cycles | |
MTTF [years] | 787 |
UL approval | Ta | -25…70 °C | Enclosure type | Type 1 | voltage supply | Limited Voltage/Current | UL Approval no. | A016 | File number UL | E174191 | |
Mechanical data |
Weight [g] | 42.7 |
Housing | rectangular |
Mounting | flush mountable |
Dimensions [mm] | 20 x 8 x 32 |
Materials | diecast zinc special coating; sensing face: PBT orange; LED window: TPU; potting: PUR |
Displays / operating elements |
Display | Display operation | 1 x LED, green | switching status | 1 x LED, yellow | |
Remarks |
Pack quantity | 1 pcs. |
Electrical connection |
Connection | Cable: 0.3 m, PUR, Ø 4.9 mm; 3 x 0.34 mm² |
Connection | Connector: 1 x M12 |